Maintain animals or perform incubation, culture maintenance and analysis in the same environment with Coy O2 control glove boxes, suitable for either in vivo or in vitro work. O2 and CO2 concentrations will need to be adjusted from their normal atmospheric air concentrations within the experimental chamber or the glove box. N2 is used as a flush gas to displace the atmospheric gas mix to the experimental pre-sets. The controllers, combined with the sealed glove box and airlock, provide a more accurate and uninterrupted environment than an incubator or cabinet system by eliminating exposure to non-experimental conditions.
Adaptable for your specific needs. Options include:
- Animal filtration system: long-term studies or high numbers of animals will require this filtration system to remove gaseous waste.
- Added capacity for animal filtration: Additional filters to enhance the filtration system and adjust for the number of animals while easing maintenance time for lab personnel
- Large capacity dehumidifier: easy-to-maintain unit provides a way to remove moisture without using a desiccant
- Recirculating atmosphere filtration system (HEPA): system filters the box atmosphere and controls contamination through a standard HEPA filter
- Sliding airlock shelf: ergonomic convenience that allows the user to slide the shelf from the airlock into the glove box interior and vice versa
- Temperature control: temperature control solutions available for animal comfort and to maintain experimental conditions
- Atmosphere Filtration System (HEPA): capsule system filters the box atmosphere and controls contamination through a standard HEPA filter
- UV Light: a combination of fluorescent and 254-nanometer UV lights provides illumination and decontamination of the work area
- Anoxic Upgrade Kit: a kit for upgrading O2 Control Glove Boxes to enable the users to create an anoxic environment, using catalyst reacting with a non-flammable hydrogen gas mix
- High Accuracy Calibration Kit: enables calibration and mounting of the O2 sensor, taking into account temperature, pressure and the dilution effects of humidity on O2 in air when it is used as the reference calibration gas
- Vacuum Sleeve: further minimise the slight amount of O2 transferred into the system when accessing the unit through the glove ports
- Feed-Thru Adaptor: electrical wiring, tubing or cords are input through factory-installed feed-thru adaptors sealed through the glove box wall
- Custom Sizing for Analytical Equipment: perform all analysis and manipulations in a controlled environment
- Microscope View Port: microscopes, valuable tools for intrabox work, are easier to use with this optically clear, flexible vinyl port
This product has met the following criteria: